This Compliance Today blog post explores the meaning of what is known in product safety certification as Conditions of Acceptability.

Conditions of acceptability only apply to recognized components, not listed components. 

Listed components are complete in construction and can be used without further design concerns. This means that during the certification of the component itself, the agency was able to either simulate the worst-case application (therefore covering all possible applications) or determine that the performance of that component regarding safety is independent of the end-application. For example, a listed power supply will always have the same I/O ratings and safety isolation, regardless of how it is employed.

Recognized components, on the other hand, are incomplete in construction and further consideration must be given to the design employing that component. Unlike a listing, during the certification of this component, the agency was not able to simulate worst-case application or determine all possible applications.

Therefore a set of application conditions must be generated in order to complete the design or ensure performance with regards to safety is not jeopardized when the component is placed into service in an end product. These are known as Conditions of Acceptability (aka CofAs) for that recognized component. 

For example, a recognized power supply will likely be for assembly into an end-product. It will likely lack an enclosure. A condition on the use of this component would be to ensure a suitable enclosure is provided when employed in the end-product.

Recognized components have conditions of acceptability detailed in their certification report. This report can be obtained from the component manufacturer. The CofAs are required to be addressed by the agency during the end-product investigation same as any other requirement from the standard.

CofAs are typically required for the following components:

  • Power supplies
  • Transformers
  • Overcurrent, overvoltage and overtemperature devices
  • Switches, if endurance or reliability is critical
  • Any other safety isolating components

It is incumbent on the client to obtain the CofAs where they are required for the project. The client is in a better position than the testing agency to obtain these documents as the client is the buyer of the component. This usually gives the vendor of the component incentive to make these documents available upon request. In most cases the CofAs can be supplied directly from the vendor and in some cases the manufacture may provide them.

Read more about the safety certification process.

1 Comment on Product Safety Conditions of Acceptability Apply to Recognized – Not Listed – Components

  1. The Conditions of Acceptability should be always made available and ensured by the testing agency during the follow-ups that this is done when the component is shipped from the factory. This can be provided by means of a stuffer sheet where there is a reference to the company website and where the conditions of acceptability can be downloaded.

    Having worked at various test laboratories in the past, I find that this is the most painful thing by manufacturers to obtain from their vendors. This delayed projects by several weeks as sometimes the vendor supplying the component had to get the C of A from another supplier who then had to get it from the manufacturer.

Comments are closed.

About Compliance Today | By MET Labs

Through our educational resources, we keep you informed on essential regulatory requirements, changes, updates, and notices on a wide range of subjects across multiple industries, topics, and trends.Have a question about Standards Interpretations, Technical Specs, Applicability of Standards, Country-Specific Requirements? Subscribe to Compliance Today by .